TYPE
T
VKT
MPAT
TG

wet pit pumps

Table of Vertical Pumps with various implementations and configurations.

Additional add-ons such as thermostat connector, fittings etc. are available.

 

 

   
 

shaft seals for handling non dangerous liquids

primary: hydrodynamic

secondary: not necessary for type "T"

primary: hydrodynamic

secondary: according to demand

primary: hydrodynamic

secondary: gas sealing and magnetic drive

primary: hydrodynamic

secondary: according to demand

shaft seals for handling toxic liquids

primary: hydrodynamic

secondary: double mechanical seal

primary: hydrodynamic

secondary: double mechanical seal

primary: hydrodynamic

secondary: gas sealing with magnetic drive

primary: hydrodynamic

secondary: double mechanical seal

transferring highly gaseous liquids

up to 35% in volume

design: AN

/

up to 35% in volume

design: AN

/
liquids with solid ingredients (no extra settings required)
max. allowable solid particle size is relative to the size of the pump
max. allowable solid particle size is relative to the size of the pump
max. allowable solid particle size is relative to the size of the pump
/
liquids with solid ingredients (with extra settings for the bearings)
/
/
/
external flushed bearings
able to run dry
(i. e. the pump can run without fluid)
yes
yes
yes
no
safe run at zero influx
i. e. the pump is gradually filled but not transporting
design: AN
no
design: AN
no
selfregulation
design: AN
no
design: AN
no
boiling liquids
design: AN
no
design: AN
no
maximum useful immersion depth
T = 1,2 m
T = 1,2 m
T = 3,5 m
T = 2 m
flow rate
max. 1500 m³/h
max. 450 m³/h
max. 60 m³/h
max. 1500 m³/h